GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
08:19 Aug 16, 2018 |
English to Czech translations [PRO] Tech/Engineering - Electronics / Elect Eng | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Pavel Prudký | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
4 | bod nasycení |
| ||
4 | bod nasycení jádra (transformátoru) |
|
bod nasycení Explanation: česky zde: http://www.ueen.feec.vutbr.cz/cz/images/stories/OPVK_ePower/... Reference: http://www.researchgate.net/post/What_is_Knee_Point_Voltage_... |
| ||
Grading comment
| |||
Notes to answerer
| |||
Login to enter a peer comment (or grade) |
bod nasycení jádra (transformátoru) Explanation: EN: "Knee Point Voltage of Current Transformer This is the significance of saturation level of a CT core mainly used for protection purposes. The sinusoidal voltage of rated frequency applied to the secondary terminals of current transformer, with other winding being open circuited, which when increased by 10% cause the exiting current to increase 50%. The CT core is made of CRGO steel." https://www.electrical4u.com/knee-point-voltage-of-current-t... CS: https://www.vutbr.cz/www_base/zav_prace_soubor_verejne.php?f... "IEC/BS: Podle normy IEC 60044 - 1 je tento bod určen tak, že nárůst napětí Ui o 10 % zvýší magnetizační proud o 50 %." |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.