3 | próba/sprawdzian szczelności układu hydraulicznego |
|
próba/sprawdzian szczelności układu hydraulicznego Explanation: This sounds like a leak test: fill with fluid, check for leaks. ccccccccccccccc PRE-OPERATIONAL FLUID TEST After all of the aforementioned procedures have been followed, the filter system is ready for a fluid test prior to being placed in full operation. 1. Close the drain valves and open the vent valve, or make sure the air eliminator is unrestricted. 2. Open the gauge cocks on the liquid level gauge if used. 3. Open the main valve from the storage tank to SLOWLY fill the system piping and filter vessel with fluid using head pressure from the storage tank. 4. If head pressure is not available, the system piping and filter vessel will need to be filled using the system pump. Instruction If Positive Displacement Pump Is Used 1. If a positive displacement pump is used in the system, a bypass line must be installed around the filter vessel, or a pressure relief valve be installed in the piping to prevent excessive pressure that may cause damage. 2. Start the system pump and SLOWLY open the main valve on the inlet piping. 3. Allow the filter vessel to fill SLOWLY and completely. 4. Close the vents and SLOWLY open the main valve on the outlet piping of the filter vessel. 5. If Fluid Mist Occurs There will be a slight emission of fluid mist when the filter vessel is on line and when the air eliminator vents, the manual vent is opened or when excess thermal pressure is discharged from the pressure relief valve. 6. Inspect all connections for leaks. 7. Tighten connections or replace gaskets where necessary. If tightening connections fails to stop leaks, inspect for damage and replace parts as necessary. 8. Check all components for proper operation and valve alignment. 9. Verify that all fluid spills have been http://www.parker.com/parkerimages/Racor/7563 (RVFS Vessel S... ccccccccccccccccccc |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.