trend limit przekroczenie granicy trendu/granicy fluktuacji Explanation: The system collects historical data that fluctuatues over time. From the graphs (http://www.impaxptg.com/pdf/impax-sk-7-manual.pdf), it appears that it is the upper fluctuation limit. cccccccccccccccc The FLOWSIC600-XT measuring system works according to the principle of ultrasonic transit time difference measurement. This allows conclusions to be made on the gas volume flowing through based on the sound velocity transfer time. Measurement is carried out in a direct path layout to keep disturbing effects such as gas flow turbulence, dirt, moisture or interfering noises as low as possible. Two ultrasonic transducers are positioned opposite each other in a defined angle to the gas flow and operate alternately as sender and receiver ----- This means the measurement conditions during calibration can be compared with the measurement conditions during start-up and with the current measurement and diagnostics data. An internal dialog continuously logs measured values which allow trend analyses to check the historical measurement process. An internal dialog continuously logs the selfmonitoring results so that a retroactive check of the measurement process in the form of a graphic trend analysis is also possible. https://www.sick.com/media/dox/8/08/908/Operating_instructio... |
| |
Login to enter a peer comment (or grade) |
2 hrs peer agreement (net): +1 |
Reference: Status messages Reference information: Category No. Description INF 1016 Restart device INF 1017 New entries in Event logbook INF 1018 Adjustment limits exceeded INF 1019 Configuration mode INF 1020 Parameter lock open INF 1021 Calibration mode INF 1022 Metrology logbook full WRN 2001 Impulse frequency > fmax WRN 2002 Ext. supply failed WRN 2003 RTC battery empty WRN 2004 Backup restore failed WRN 2005 Pressure sensor failed WRN 2006 Temperature sensor failed WRN 2007 Internal PT sensor failed WRN 2008 Warning path failure WRN 2009 Flow profile limit exceeded WRN 2010 System warning threshold exceeded WRN 2011 Trend limit exceeded ERR 3001 Event logbook full ERR 3002 Totalizer checksum error ERR 3003 Firmware checksum error ERR 3004 Parameter invalid ERR 3005 Archive checksum error ERR 3006 Time invalid ERR 3007 System test active ERR 3008 Run-time measurement mode ERR 3009 DSP hardware failed ERR 3010 DSP parameter invalid ERR 3011 Error path failure https://www.sick.com/media/dox/8/08/908/Operating_instructio... - page 66 -------------------------------------------------- Note added at 2 hrs (2017-09-21 10:45:31 GMT) -------------------------------------------------- http://valveproducts.metso.com/documents/neles/IMOs/en/7NDX7... - page 58 |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.