German to English translations [PRO] Tech/Engineering - Medical: Instruments / Stent crimping process | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: andres-larsen Venezuela Local time: 02:22 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
4 +1 | Stent removal force |
| ||
1 | stent dislodgement force |
|
Stent removal force Explanation: stent, is a thin tube inserted into the ureter to prevent or treat obstruction of the urine flow from the kidney and here they want to probably remove it |
| |
Login to enter a peer comment (or grade) |
stent dislodgement force Explanation: stent dislodgement force sources: Dislodgement Force ISO 25539 - EndoLab https://www.endolab.org/implant-testing.asp?...Dislodgement ... Stent dislodgement force test. ... ISO 25539 Profile/diameter test ISO 25539 Simulated use – Pushability, Torquability, Trackability ISO 25539 Force to deploy ISO ... Example Balloon-Expandable Stent Crimping Processes - Blockwise ... www.blockwise.com/.../MS012-ExampleBalloonExpandableCrim... means of a radial compression process known as stent crimping. This article describes an ... the stent, to increase stent dislodgement force. When possible, the ... Crypton - Meril www.merillife.com/crypton.aspx - Novel Stent Geometry. CRYPTON novel hybrid ... Great Trackability & Pushability. CRYPTON ... Unique Crimping Technique - High Stent Dislodgement Force. The need for stentlesion matching to optimize outcomes of ... https://www.uakron.edu/.../2f590dd1-29e2-4c40-b979-06dde154.... P Lanzer - 17 may. 2013 - The trackability is the ability of an SDS to pass along a guiding catheter and ... proximally applied forces, the higher pushability and greater ability to ... larger profiles in the region of the crimped stent.16. Crossability of an SDS ... comparison of dislodgement forces measured for stent systems without and ... US20110190864A1 - Stent and stent delivery system with improved ... https://www.google.com/patents/US20110190864 - In some embodiments, stent system trackability expressed as peak force over ... In some embodiments, the stent system pushability is measured according to ...... in a maximum outer diameter (profile) of the mounted (crimped) stent of 1.12 mm. ...... Cardiovascular Systems Inc. Method for measuring stent dislodgement force. Instrumentation for Coronary Artery Interventions | SpringerLink https://link.springer.com/10.1007/978-3-642-37078-6_67 - 2 feb. 2015 - Stent designed for limited residence time in coronary arteries; following ... include pushability, crossability, trackability, and torqueability ...... the stent will leave its original crimp position (stent dislodgement force) and the force ... Instrumentation | SpringerLink https://link.springer.com/chapter/10.1007/978-3-642-27676-7_... - 1 jun. 2012 - The trackability is the ability of an SDS to pass through a curved vessel path. ... The pushability is the ability to advance an SDS in coronary vessels .... stent will leave its original crimp position (stent dislodgement force) and the force ... A comparison of dislodgement forces measured for stent systems before ... |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.