Oct 18, 2007 07:07
16 yrs ago
English term

decreasing the cross-sectional area

English to German Tech/Engineering Materials (Plastics, Ceramics, etc.)
The conclusion of this investigation found the failure of the oscillator was the direct result of corrosion on the inside surface decreasing the cross-sectional area with final failure occurring by fatigue.
Change log

Oct 26, 2007 08:50: Steffen Walter changed "Field" from "Medical" to "Tech/Engineering" , "Field (specific)" from "Medical (general)" to "Materials (Plastics, Ceramics, etc.)"

Discussion

Steffen Walter Oct 18, 2007:
Was hat dieser Text mit Medizin zu tun?

Proposed translations

+4
53 mins
Selected

Reduzierung des Querschnitts

bis zum Ausfall durch Materialermüdung...
Peer comment(s):

agree Steffen Walter
43 mins
agree Cathrin Cordes
1 hr
agree Dr.G.MD (X)
5 hrs
agree Susanne Rindlisbacher
10 hrs
Something went wrong...
4 KudoZ points awarded for this answer.
+1
11 mins

..die Querschnittfläche einengt ..

corrosion on the inside surface decreasing the cross-sectional area with final failure occurring by fatigue

..Korrosion an der Innenseitenoberfläche, welche die Querschnittfläche einengt, wobei der letztendliche Ausfall durch Ermüdung erfolgte.