Mar 13, 2012 00:48
12 yrs ago
1 viewer *
German term

exfrei

German to English Tech/Engineering Chemistry; Chem Sci/Eng Designation of work areas
Here is the context sentence:
Die Räume und die Anlagen sind exfrei, deshalb sind Reinigungsarbeiten mit Lösemitteln nicht gestattet.
Proposed translations (English)
3 +2 explosion prone
5 Ex-free

Discussion

hazmatgerman (X) Mar 17, 2012:
@S.P. as I found this discussion to be futile, I leave the question.
Sven Petersson Mar 17, 2012:
@hazmatgerman, I have not claimed that the term is Dräger's; I have advised you to phone Dräger and ask if you still are in doubt; the reason for my advice being that I know that Dräger has the highest professional expertise on the subject.
Bernd Runge Mar 13, 2012:
Aha Wo genau war da noch der Unterschied?
Wenn keine explosionsauslösenden Stoffe vorhanden sind, ist der Bereich nicht explosionsgefährdet, also non-hazardous.
Und, soweit ich weiß, verlangen Räume und Anlagen (im Sinne von Equipment) sowieso unterschiedliche Einteilungen (0/1/2 bzw. 20/21/22 gegenüber IIa/b/c oder 1,2,3).
MalteLaurids Mar 13, 2012:
Ex-frei heisst ja nicht "nicht explosionsgefährdet", sondern frei von allem, was eine Explosion auslösen könnte, daher sind auch Lösungsmittel verboten.
Bernd Runge Mar 13, 2012:
Verwirrt Warum sollte die Reinigung mit Lösemitteln in nicht explosionsgefährdeten Bereichen verboten sein? Vielleicht sollte hier lieber einer Plausibilitätsprüfung anstatt einer Übersetzung Priorität eingeräumt werden ;-)
Bei Reinigung mit Lösemitteln würde der Bereich vielleicht in Zone 2 hochrutschen, wofür normal sichere Geräte (Kategorie 3) immer noch ausreichend wären ...
David Hollywood Mar 13, 2012:
can you provide a liitle more context?

Proposed translations

+2
1 hr
Selected

explosion prone

I would say it means there is a risk of explosion so you have to be careful not to use any products that might trigger one

www.knovel.com/web/portal/browse/display?_EXT_KNOVEL...4 Feb 2004 – Classifying Explosion-Prone Areas for the Petroleum, Chemical and Related ... The Extent of Explosion Danger for NEC Class I Locations. Text ...

--------------------------------------------------
Note added at 1 hr (2012-03-13 02:02:02 GMT)
--------------------------------------------------

the source text specifically states "Reinigungsarbeiten mit Lösemitteln nicht gestattet" i.e. all solvents must be avoided so this would indicate that the areas in question are prone to explosions

--------------------------------------------------
Note added at 4 hrs (2012-03-13 04:59:05 GMT)
--------------------------------------------------

regardless of the way it is expressed in German

--------------------------------------------------
Note added at 2 days2 hrs (2012-03-15 03:11:21 GMT)
--------------------------------------------------

"exfrei" has to mean "an area that totally excludes the risk of explosions"
Peer comment(s):

agree Judith Shiozawa (X) : I agree with your answer and logic and with Bernd's suggestion.
5 hrs
thanks jashio :)
agree Michael McWilliam : I agree with "explosion prone", commonly used in US English.
10 days
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thanks for your help everyone! - Including the very useful discussion that help clarify."
40 mins

Ex-free

Source should have read: "Ex-frei"

--------------------------------------------------
Note added at 45 mins (2012-03-13 01:33:57 GMT)
--------------------------------------------------

http://www.pkp.de/produkte/pdf_bed/ps08-bed-e.pdf?PHPSESSID=...

http://www.pofscales.ie/download.aspx?f=Bizerba STeX Flyer.p...


--------------------------------------------------
Note added at 4 days (2012-03-17 10:09:23 GMT)
--------------------------------------------------

Info for hazmatgerman:

An Ex-free area is an area in which electrical devices that are not themselves explosion-proof can be mounted and operated.

--------------------------------------------------
Note added at 4 days (2012-03-17 12:27:21 GMT)
--------------------------------------------------

If still in doubt, call Dräger and ask (+49 451 882-0).
Something went wrong...

Reference comments

25 mins
Reference:

absence of explosive atmosphere

Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search