Parametry modułu PV. Fault level contribution to hasło nad tabelą, a dalej:
Short-circuit current at micro-generator terminals
As Photovoltaic SSEGs are inverter connected, they are deemed to automatically comply with regulations and
no further tests are required.
Short-circuit current at micro-generator terminals
As Photovoltaic SSEGs are inverter connected, they are deemed to automatically comply with regulations and
no further tests are required.
Proposed translations
(polski)
2 | udział do poziomu prądu zwarciowego/udział w prądzie zwarciowym | Frank Szmulowicz, Ph. D. |
Change log
Sep 7, 2017 20:18: Frank Szmulowicz, Ph. D. Created KOG entry
Proposed translations
3 godz.
Selected
udział do poziomu prądu zwarciowego/udział w prądzie zwarciowym
I understand this to mean that there are several contributions to the level of the fault current.
ccccccccccccc
prad obciazeniowy i zwarciowy load current/ short-circuit current (fault current)
http://www.proz.com/personal-glossaries/entry/9734644-prad-o...
ccccccc
CALCULATION OF THE FAULT LEVEL CONTRIBUTION OF DISTRIBUTED GENERATION ACCORDING TO IEC STANDARD 60909 TH. BOUTSIKA S. PAPATHANASSIOU∗ N. DROSSOS National Technical University of Athens (NTUA) Public Power Corporation (PPC) Greece Keywords: Short-Circuit Current (SC Current) - Fault Level - Distribution Network (DN) - Distributed Generation (DG) 1. INTRODUCTION Distribution networks are characterized by a design short-circuit (sc) capacity, i.e. a maximum fault current to be never exceeded, related with the rating of switchgear and the thermal and mechanical endurance of all equipment and standardized constructions. Distributed generation (DG) resources are typically connected to distribution networks, at the low or medium voltage level, and therefore contribute to the total fault level of the network, roughly determined by the combined short-circuit contributions of the upstream grid and the various DG sources within the distribution network
https://documentslide.com/documents/calculation-of-the-fault...
ccccccccc
2.2 Uzgodnienia projektowe
Na podstawie informacji dostarczonych przez użytkownika dostawca energii musi
podać
Wielkość mocy (kVA) i poziom prądu zwarciowego
Koszt rozdzielnicy jest najczęściej mniejszy (poziom prądu zwarciowego jest niższy).
ocena poziomów doziemnych prądów zwarciowych na etapie projekto
http://www2.schneider-electric.com/resources/sites/SCHNEIDER...
cccccccc
W przypadku mikroźródeł należy również pamiętać, że takie
źródło wnosi określony udział w prądach zwarciowych podczas
wystąpienia zwarcia w takiej sieci.
https://yadda.icm.edu.pl/baztech/element/bwmeta1.element.baz...
cccccccccc
Kraje europejskie posiadają
kodeks sieci, który określa obowiązki zarówno operatorów systemów dystrybucyjnych, jak i wytwórców przyłą-
czonych do sieci (np. charakterystyki regulacji, udział w prądzie zwarciowym itp.).
http://copperalliance.eu/docs/librariesprovider3/8_1_generac...
ccccccccccccc
prad obciazeniowy i zwarciowy load current/ short-circuit current (fault current)
http://www.proz.com/personal-glossaries/entry/9734644-prad-o...
ccccccc
CALCULATION OF THE FAULT LEVEL CONTRIBUTION OF DISTRIBUTED GENERATION ACCORDING TO IEC STANDARD 60909 TH. BOUTSIKA S. PAPATHANASSIOU∗ N. DROSSOS National Technical University of Athens (NTUA) Public Power Corporation (PPC) Greece Keywords: Short-Circuit Current (SC Current) - Fault Level - Distribution Network (DN) - Distributed Generation (DG) 1. INTRODUCTION Distribution networks are characterized by a design short-circuit (sc) capacity, i.e. a maximum fault current to be never exceeded, related with the rating of switchgear and the thermal and mechanical endurance of all equipment and standardized constructions. Distributed generation (DG) resources are typically connected to distribution networks, at the low or medium voltage level, and therefore contribute to the total fault level of the network, roughly determined by the combined short-circuit contributions of the upstream grid and the various DG sources within the distribution network
https://documentslide.com/documents/calculation-of-the-fault...
ccccccccc
2.2 Uzgodnienia projektowe
Na podstawie informacji dostarczonych przez użytkownika dostawca energii musi
podać
Wielkość mocy (kVA) i poziom prądu zwarciowego
Koszt rozdzielnicy jest najczęściej mniejszy (poziom prądu zwarciowego jest niższy).
ocena poziomów doziemnych prądów zwarciowych na etapie projekto
http://www2.schneider-electric.com/resources/sites/SCHNEIDER...
cccccccc
W przypadku mikroźródeł należy również pamiętać, że takie
źródło wnosi określony udział w prądach zwarciowych podczas
wystąpienia zwarcia w takiej sieci.
https://yadda.icm.edu.pl/baztech/element/bwmeta1.element.baz...
cccccccccc
Kraje europejskie posiadają
kodeks sieci, który określa obowiązki zarówno operatorów systemów dystrybucyjnych, jak i wytwórców przyłą-
czonych do sieci (np. charakterystyki regulacji, udział w prądzie zwarciowym itp.).
http://copperalliance.eu/docs/librariesprovider3/8_1_generac...
4 KudoZ points awarded for this answer.
Comment: "Dziękuję!"
Reference comments
1 godz.
Reference:
Calculation of the fault level contribution of distributed generation to distribution network
ABSTRACT
Paper deals with the calculation of the fault level contribution of distributed generation according to IEC Standard 60909. To illustrate its application, the methodology is applied to a study medium voltage network with a variety of distributed generation resources.
1. INTRODUCTION Distribution network are characterized by design maximum fault current, i.e. short-circuit capacity. Distributed generation resources are typically connected to the distribution network, at the low or medium voltage level. Therefore they contribute to the total fault level of the distribution grid. Hence, the basic requirement for permitting the interconnection of distributed generation resources is to ensure that the resulting fault level remains below the network design value.
http://home.zcu.cz/~tesarova/IP/Proceedings/Proc_2006/Files/...
Paper deals with the calculation of the fault level contribution of distributed generation according to IEC Standard 60909. To illustrate its application, the methodology is applied to a study medium voltage network with a variety of distributed generation resources.
1. INTRODUCTION Distribution network are characterized by design maximum fault current, i.e. short-circuit capacity. Distributed generation resources are typically connected to the distribution network, at the low or medium voltage level. Therefore they contribute to the total fault level of the distribution grid. Hence, the basic requirement for permitting the interconnection of distributed generation resources is to ensure that the resulting fault level remains below the network design value.
http://home.zcu.cz/~tesarova/IP/Proceedings/Proc_2006/Files/...
Something went wrong...