08:21 Feb 3, 2020 |
English to Russian translations [PRO] Tech/Engineering - Electronics / Elect Eng | |||||
---|---|---|---|---|---|
|
| ||||
| Selected response from: mk_lab Ukraine Local time: 23:40 | ||||
Grading comment
|
номинал и тип предохранителя Explanation: Как возможный вариант -------------------------------------------------- Note added at 11 mins (2020-02-03 08:32:39 GMT) -------------------------------------------------- Предохранитель Kicx ATCFB15A25-20 Номинал и тип предохранителя: 15A ATC http://kicx-shop.ru/connectors_kicx/tproduct/119868933-35297... -------------------------------------------------- Note added at 18 mins (2020-02-03 08:39:41 GMT) -------------------------------------------------- Номинал и типоразмер -------------------------------------------------- Note added at 21 mins (2020-02-03 08:42:31 GMT) -------------------------------------------------- 5 Характеристики плавких предохранителей ... Стандартные значения номинального переменного напряжения: 400 В для предохранителей типоразмеров D01, D02 и D03*, 500 В для предохранителей типоразмеров Dll, DIII и DIV. Значения постоянного номинального напряжения: 250 В для предохранителей типоразмеров D01, D02 и D03*, 500 В для предохранителей типоразмеров DII, DIII и DIV. http://docs.cntd.ru/document/1200100795 |
| |
Login to enter a peer comment (or grade) |
fuse value/rating valore / grado del fusibile Explanation: valore / grado del fusibile |
| |
Login to enter a peer comment (or grade) |
fuse value/rating ток срабатывания / номинальный ток предохранителя Explanation: ток срабатывания / номинальный ток (плавкой вставки) предохранителя Это разные (хотя и связанные) значения, которые зависят от конструкции, режимов работы и времени перегрузки. Так, например, при одном и том же номинальном токе одни предохранители, рассчитанные на длительную перегрузку, не сработают при кратковременном КЗ, а другие - сработают. Выбор и проверка защитной аппаратуры низковольтных сетей - Защита плавкими предохранителями https://forca.com.ua/instrukcii/rospodilni-merezhi/vybor-i-p... Ток срабатывания плавкого предохранителя определяют как ток, приводящий к срабатыванию предохранителя за время, достаточное для достижения установившегося теплового состояния (за время от 1 до 4 ч в зависимости от номинального тока плавкого элемента). Ток, который в этих условиях не приводит к срабатыванию предохранителя, называют током несрабатывания. Среднее геометрическое этих двух токов называют пограничным током предохранителя -------------------------------------------------- Note added at 2 hrs (2020-02-03 11:05:19 GMT) -------------------------------------------------- Т.е., номинальный ток - это характеристика только лишь плавкого элемента, а ток срабатывания - это результирующий параметр всего предохранителя, зависящий от номинала плавкого элемента, теплоотвода контактов, геометрии и условий работы предохранителя, на которые он рассчитан. |
| |
Login to enter a peer comment (or grade) |
fuse value/rating номинальные значения предохранителя Explanation: Для плавких предохранителей НЕТ разных терминов value и rating. Стандартный термин - rating, но вместо него иногда используют value (например, в указанном ниже стандарте IEC 60269-1-2014 в разделе 1.1 среди характеристик предохранителей упоминаются their rated values) Либо в контексте and идет в смысле ИЛИ, либо речь идет о значениях нескольких параметров, как показано ниже. Определение из стандарта IEC 60269-1-2014 Low-voltage fuses — Part 1: General requirements 2.3.1 rating: general term employed to designate the characteristic values that together define the working conditions upon which the tests are based and for which the equipment is designed [IEV 441-18-36] NOTE Rated values usually stated for low-voltage fuses are: voltage, current, breaking capacity, power dissipation and acceptable power dissipation, and frequency, where applicable. In the case of a.c., rated voltage and rated current are stated as r.m.s. symmetrical values; in the case of d.c., when ripple is present, the rated voltage is stated as a mean value, the rated current as an r.m.s. value. The above applies to any value of voltage and current, if not indicated otherwise. И аналогичное определение из нашего перевода этого стандарта ГОСТ IEC 60269-1-2016 Предохранители плавкие низковольтные. Часть 1. Общие требования https://files.stroyinf.ru/Data2/1/4293745/4293745603.pdf 2.3.1 номинальные значения (rating): Общий термин, обозначающий значения параметров, которые в совокупности определяют рабочие условия, в соответствии с которыми проводят испытания и на которые рассчитано оборудование. Примечание — Для низковольтных плавких предохранителей обычно указывают номинальные значения напряжения, тока, отключающей способности, потерь мощности, рассеиваемой мощности и частоты (при необходимости). Для переменного напряжения номинальное напряжение и номинальный ток задают в виде действующих симметричных значений. Для постоянного напряжения при наличии пульсации номинальное напряжение задают в виде среднего значения, номинальный ток — в виде действующего значения. Это относится ко всем значениям напряжения и тока, если не оговорено иное. [IEC 60050-441, статья 441-18-36] Поскольку rating - это группа параметров для описания предохранителя, то value рядом с ним выглядит как нонсенс. И немного о других терминах. Номинальный ток - это ток, который предохранитель способен пропускать как угодно долго. Параметра "ток срабатывания" для предохранителей нет, есть ток отключения, который определяется по времятоковой кривой и не нормируется, просто чем больше ток, тем быстрее произойдет отключение. Вообще для предохранителя определено много параметров с размерностью тока - (макс.) отключающая способность (какой ток он способен отключить), пропускаемый ток (макс. ток в процессе отключения), ток плавления, ток неплавления, есть еще параметры напряжения, времени, температуры. Поэтому что именно они имели в виду под value and rating на задней панели - большой вопрос. Лучше переводить самым общим термином, хотя у держателя предохранителя обычно указывают номинальный ток и (иногда напряжение и (редко) тип). |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.