Glossary entry

Portuguese term or phrase:

pressão de recalque da bomba

English translation:

the pump's booster pressure

Added to glossary by Terje Ostgaard
Mar 31, 2005 16:11
19 yrs ago
1 viewer *
Portuguese term

pressão de recalque da bomba

Portuguese to English Tech/Engineering Mining & Minerals / Gems
In translating a Risk Assessment Report done by an insurance company for a mine in Brazil, the following phrase appears: "À vazão 0, a pressão de recalque da bomba não deve ultrapassar 140% de sua pressão nominal." In this context "pressão de recalque" seems to be in contrast with "pressão de descarga da bomba." Many thanks in advance for your help!

Douglas

Proposed translations

51 mins
Portuguese term (edited): press�o de recalque da bomba
Selected

the pump's booster pressure

;)
Something went wrong...
3 KudoZ points awarded for this answer. Comment: "Many Thanks!"
14 mins
Portuguese term (edited): press�o de recalque da bomba

pressure booster pump

perhaps this is the term you're looking for

See
http://www.globalspec.com/ProductFinder/FindProducts?query="...
Something went wrong...
9 hrs
Portuguese term (edited): press�o de recalque da bomba

pump shut-off pressure (in this case)

This is the expression used to describe the pump pressure when the rate-of-flow is zero. Check at these examples:

Canariis Corporation - UL Listed Packaged Pumping Systems
... "PUMP SHUT OFF PRESSURE" in PSIG is the pressure added by the pump(s) at zero flow. "PUMP DUTY POINT" is the pump design capacity in GPM, ...
www.canariis.com/design/definitions.html

[PDF] Smart Tank IOM.qxd
File Format: PDF/Adobe Acrobat - View as HTML
... NOTE: If the pump does not shut off this could indicate that the pump shut off pressure does not exceed the pressure switch ...
www.flexconind.com/pdf/st_install.pdf

[PDF] ABDCFEG
File Format: PDF/Adobe Acrobat - View as HTML
... Pump shut-off pressure is 65 PSI [4.5 Bar]. System must be designed to handle 65 PSI [4.5 Bar]. •Pump draws 15 milliamps continuously when pump switch ...
www.shurflo.com/pdf/rv/ 911_trouble_shooting/911-594-D.pdf

OCV | Pump Control Valve Series 125
... or if the maximum pressure (typically pump shut off pressure) is greater than 400 psi, your only choice will be the single-chambered valve. ...
www.controlvalves.com/series/125/125_selection.html


--------------------------------------------------
Note added at 9 hrs 15 mins (2005-04-01 01:26:18 GMT)
--------------------------------------------------

The general translation for \"pressão de recalque da bomba\" is \"pump discharge pressure\". In this particular case, when there is no flow, use PUMP SHUT-OFF PRESSURE.
Something went wrong...