Glossary entry

French term or phrase:

isolateur

English translation:

lockout/tagout operator

Added to glossary by Marco Solinas
Dec 7, 2012 16:00
11 yrs ago
3 viewers *
French term

isolateur

French to English Tech/Engineering Mechanics / Mech Engineering Lock out or tag out procedure
From the description of a lock-out procedure:

"La prise de contact avec un *isolateur* a-t-elle été effectuée en cas de besoin de consignation?"

"Vérification de la fiche de consignation avec l’*isolateur* désigné ?"

"L’émetteur de permis doit vérifier que la fiche de consignation est complétée et signé par l’isolateur et le témoin."

The context makes it clear that the "isolateur" is the person that locks out or tags out the equipmednt, but I am unable to find the right English equivalent.

All suggestions are welcome.

Proposed translations

+4
27 mins
Selected

lockout/tagout operator

Or you could say technician instead of operator.
Example sentence:

Perform regular machine maintenance during tool turn around. Trained as a Lockout-Tagout operator.

LOCKOUT TAGOUT TECHNICIAN: ... Able to read prints, schematics and trace circuits and piping to ensure isolation of energy source to provide employee protection.

Peer comment(s):

agree chris collister : Though "consignation" appears in the same sentence. Too many tagouts?
30 mins
agree Tony M : Too many or not, there's no getting round the use of the proper technical term
33 mins
agree Hacia
1 hr
agree FoundInTrans : in retrospect yes, great refs.
6 hrs
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thank you Phil"
9 mins

Isolation worker

Termium is a site that backs up its translations with sources. That's what I found in "Occupation name". Hope it helps.
Note from asker:
Thank you Lyne. I am not certain that the Termium reference applies in this case. Termium refere to thermal insulation. My case is quite different.
Something went wrong...
-1
12 mins

authorised associate

See link

--------------------------------------------------
Note added at 13 mins (2012-12-07 16:14:36 GMT)
--------------------------------------------------

From the link :

Authorized associate: This is an associate who performs servicing or maintenance on equipment and machinery. This associate implements lockout/tagout procedures to guarantee his or her own protection.
Peer comment(s):

disagree Tony M : Your reference only refers to a specific case, but could not be extrapolated to a general situation. / It would be a translation error, since it does not convey the key meaning of the source term.
46 mins
I think a disagree is harsh here, it may not be the best translation but it is not wrong per se. A neutral would be more appropriate since better has emerged I understand.
Something went wrong...
-1
18 mins

Isolator

Peer comment(s):

neutral philgoddard : You've just Googled "isolator" and put the first hit as a reference, even though it's completely irrelevant to the context.
29 mins
neutral chris collister : "isolator" is usually a "thing", though here the context makes clear he/she is a person
37 mins
disagree Tony M : Your reference is not relevant to this context, and in EN this would be taken as meaning the physical device.
41 mins
Something went wrong...
10 hrs

lockout/tagout installer or worker

The
procedure should identify:
`` the person responsible for performing the lockout (for example, operator, millwright, electrician)
http://www.iapa.ca/pdf/lockout.pdf

The operator who positioned the valve and installed the lockout/tagout was not standing in the correct position to manipulate the chain-operator and incorrectly assumed the direction to operate the chain.
The operators (a lockout/tagout installer and an independent verifier) involved in the valve lineup were not fully aware or familiar with the proper techniques for opening and closing chain-operated valves, valve seating position, and attention to visual indicators.
http://www.hss.doe.gov/sesa/Analysis/electrical/loto4.pdf

The lockout/tagout installer verified the adequacy of the lock and the locking device as required by both 29 CFR 1910.333 and NFPA 70E, section 120.2, to ensure the lock was attached in a way to prevent anyone from operating the device unless they resorted to using undue force or tools.
http://www.hss.energy.gov/sesa/analysis/oesummary/oesummary2...

52 11/15/2007 Parsons
Lockout/Tagout Program for Test Equipment
Specific to test equipment location and organization conducting testing
Lockout/tagout installer/checker training/qualification
Lockout/tagout log and control
http://www.pdfio.com/k-2018108.html

Lockout/Tagout - Occupational Safety and Health ...
Lockout/Tagout Worker Training of Electrical Hazards Including Arc Flash SH-16614-07 This material was produced under grant number SH-16614-07 from the Occupational ...
http://freedownloadb.com/ppt/lockout-tagout-training
http://freedownloadb.com/ppt/blockout-b-btagout-b-occupation...

Leigthon Contractors Indonesia) • JSEA • Take 5 • Hot Work Permit • Waste Management • Hydrocarbon Management • Chemwatch • Lockout & Tagout Worker ...
http://www.google.de/url?sa=t&rct=j&q="tagout worker"&source...

Trained as a Lockout-Tagout operator.
http://www.linkedin.com/pub/matthew-bierlein/61/182/9a2

AUTHORIZED PERSON
A person who has completed lockout/tagout training, and has been appointed, and is authorized to lock and tag equipment as a representative of the Village of Ruidoso.
http://manuals.se/download.php?manual=9d6ddcc8f0bd726eac5607...

Note: Found less Google hits for 'lockout/tagout operator' than for 'lockout/tagout worker'. See also Reference.
Something went wrong...

Reference comments

9 hrs
Reference:

LOTO

Lockout-tagout (LOTO) or lock and tag is a safety procedure which is used in industry and research settings to ensure that dangerous machines are properly shut off and not started up again prior to the completion of maintenance or servicing work. It requires that hazardous power sources be "isolated and rendered inoperative" before any repair procedure is started. "Lock and tag" works in conjunction with a lock usually locking the device or the power source with the hasp, and placing it in such a position that no hazardous power sources can be turned on. The procedure requires that a tag be affixed to the locked device indicating that it should not be turned on.
http://en.wikipedia.org/wiki/Lockout-tagout

All employees who are authorized to lockout machines or equipment and perform the service and maintenance operations need to be trained in recognition of applicable hazardous energy sources in the workplace, the type and magnitude of energy found in the workplace, and the means and methods of isolating and/or controlling the energy.
http://www.osha.gov/SLTC/controlhazardousenergy/index.html

Only authorized employees should provide worker training [29 CFR 1910.147 (c)(7)(I)]. Training must include the energy-control procedure uses and purposes, and all workers in the area where the energy-control procedures are used. When tagouts are used, employees must be taught of the devices' limitations.
http://www.google.de/#hl=de&tbo=d&rlz=1R2MXGB_deDE509&biw=12...

During lockout/tagout, a person authorized by the company places locks and/or tags on energy-isolating devices before working on equipment, and only that person can remove those locks and tags. Isolation devices are mechanical appliances, such as circuit breakers, used to stop energy from being released to the equipment. Lockout is usually accomplished with a keyed lock holding an isolating device in an “off” position. Tagout, which is often used when lockout can’t take place, uses tags to warn people that the equipment and isolating device may not be operated.
http://www.reliableplant.com/Read/1624/lockout-tagout
Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search